Article

Presbyopia lens provides good vision at all distances with minimal disturbances

Author(s):

Reviewed by Mike P. Holzer, MD

Bilateral implantation of the Precizon Presbyopic NVA Multifocal IOL (Ophtec) provides “satisfying” uncorrected vision at all distances for patients undergoing cataract surgery or clear lens extraction, according to Mike P. Holzer, MD, an ophthalmologist in private practice in Weinheim, Germany.

The company describes this technology as a hybrid, acrylic IOL with a continuous transitional focus (CTF) optic to correct presbyopia, which according to Holzer is a key feature of this IOL. CTF provides seamless transition from one distance to another. The lens is not currently approved by the FDA.

The lens is available in powers ranging from +1.0 to +35.0 D in 0.5-D increments, with an add-on power of +2.75 D. The lens was evaluated in a multicenter, prospective, open-label, single-arm clinical trial (NCT02409771) that looked at the base 10 logarithm of the minimum angle of resolution (logMAR) corrected and uncorrected visual acuity (VA) scores at distance, intermediate, and near; the manifest refraction spherical equivalent; and the defocus curve. Fifty-nine patients were included in the study. All patients in the study underwent bilateral implantation of the IOL.

The results showed that 84% of the patients were within 0.5 D of emmetropia. The investigators observed a slight hyperopic shift. Therefore the constants for the IOL calculation were adjusted. The mean bilateral uncorrected VAs were 0.0 for distance, 0.14 for intermediate, and near 0.2 for near logMAR.

When asked about visual disturbances, most of the patients reported never or almost never having glare or halos. When these visual disturbances did occur, patients reported that they were not bothersome.

“All surgeries for implantation of the IOL were uneventful. The IOL provided very good [VAs] at all distances from far to near. Low percentages of halo and glare occurred. The Precizon Presbyopic IOL implantation is an effective method to provide good [VA] at all distances in presbyopic and cataract patients,” Holzer concluded.

Mike P. Holzer, MD

E: info@augenzentrum-holzer.de

This article is adapted from Holzer’s presentation at the 2022 American Society of Cataract and Refractive Surgery’s Annual Meeting in Washington, DC. The study he presented was supported by Ophtec BV, Groningen, the Netherlands.



Related Videos
Arun Gulani, MD: How the Gni instrument enhances precision and control in cataract surgery
Kamran M. Riaz, MD, an expert on IOLs
Kamran M. Riaz, MD, an expert on IOLs
Kamran M. Riaz, MD, an expert on IOLs
Kamran M. Riaz, MD, an expert on IOLs
EyeCon 2024: Peter J. McDonnell, MD, marvels on mentoring, modern technology, and ophthalmology’s future
EyeCon Co-chair Oluwatosin U. Smith, MD: Passion for Research and Education Drives Her Commitment to Ophthalmology
© 2024 MJH Life Sciences

All rights reserved.