Qualitative analysis still the gold standard for detecting glaucoma progression

Both quantitative and qualitative methods of detecting glaucomatous progression are useful, but optic disk photography remains the gold standard. New software for statistical analysis is helpful but should be an adjunct used with more established approaches.

Key Points

New Orleans-Which is better at detecting glaucomatous progression: the physician's judgment, based on skills such as interpreting optic disk photographs, or new technologies? Both have a role, but to Joseph Caprioli, MD, FACS, who discussed detection strategies in a presentation at the American Academy of Ophthalmology annual meeting, qualitative evaluation techniques retain an edge.

According to Dr. Caprioli, the best way to detect progression is through careful evaluation of structure.

Disk photographs are still the gold standard, whereas quantitative measurements are adjunctive. Selective use of short-wavelength automated perimetry and frequency doubling perimetry is helpful in making an early diagnosis of glaucoma in ocular hypertensive patients or otherwise suspect patients, he said, but the variability of those tools makes assessing changes over time difficult. Instead, serial evaluation of standard automated perimetry, multiple tests, and validation are the keys to detecting progression.

"I'd like to put forward a concept that measurement of progression rate is more important than early detection, and that the functional and structural scales by which we measure progression are not synchronous or even linear. They may not be synchronous in early disease and particularly in late disease," Dr. Caprioli said.

For example, he continued, it would be important to be able to differentiate slow progressors from fast progressors, since fast progressors require aggressive treatment, particularly early rather than late, to preserve visual function.

The main challenge in functional testing is long-term fluctuation, due to an inherent signal-to-noise problem, Dr. Caprioli said, with the signal being real progression and the noise being long-term fluctuation. "To solve that problem, we need multiple tests that tend to average out or cancel out the noise and reveal the true signal, and the true signal needs confirmation with subsequent tests."

Dr. Caprioli also pointed out that many patients have such high long-term fluctuation that evaluating any two visual fields could show that the patient is getting better, getting worse, or remaining stable. "Important lesson: never evaluate visual fields based on two measurements," he said.

Dr. Caprioli also described some of the new technology designed to identify progression with visual fields. Glaucoma Change Probability Analysis and its upgraded version, Glaucoma Progression Analysis, are software programs used with a visual field testing platform (Humphrey Field Analyzer, Carl Zeiss Meditec). Those programs compare every point to a baseline set of points from two, three, or more fields and determine whether there is a probability for change and whether that change has been confirmed. When interpreting the results, look for a solid triangle showing a statistical change at a point that has been confirmed twice and for groupings of those points, which makes sense clinically, Dr. Caprioli said. If the disk is examined over the same period, it is likely that significant change will be seen, he added.

Dr. Caprioli also discussed the merits of probability in predicting whether the visual field will progress over time. He suggested, based on work he has done, statistical software can help with that type of prediction.

He concluded by offering his seven rules for recognizing visual field progression: