Controlling adult glaucoma with cataract surgery, stent

Hydrus mechanism

Studies have shown IOP lowering associated with procedure in patients with POAG

In the United States, more than 3 million Americans suffer from glaucoma. This is the second-leading cause of blindness worldwide. Now a new procedure is here to relieve the mechanism and symptoms of the disease and help prevent blindness.

Glaucoma is caused by damage to the optic nerve described as cupping. While there are known genetic risk factors, the only manageable symptom is elevated eye pressure. Elevated pressure damages the optic nerve and can result in vision loss and blindness if not treated properly.  

Traditionally, most glaucoma patients use eye drops to lower pressure and relieve the stress on the optic nerve. Unfortunately, eye drops must be taken for as long as the patient lives, and as a result, managing the use of eye drops-which sometimes need to be administered multiple times during the day-can be cumbersome.

Research has shown that as few as 50% of patients stay on their prescribed medicines past six months. Eye drops do not address the mechanism of glaucoma.

The most common form of glaucoma is primary open-angle glaucoma (POAG), and is characterized by reduced aqueous outflow resulting in elevated eye pressure. In patients over 50 years of age, the cataract, or enlarged lens, is the most common identifiable cause of glaucoma in my practice.

Aqueous drainage depends on a functioning trabecular meshwork and a patent canal of Schlemm. The enlarged lens compresses Schlemm’s canal and creates pigment liberation by rubbing against the posterior iris. The pigment is trapped in the trabecular meshwork, further reducing flow and elevating pressure.

Survey results
In the Baltimore Eye Survey, the mean normal IOP in patients without glaucoma was about 15 mm Hg and the mean IOP in patients with glaucoma is 18 mm Hg.1

For glaucoma patients with age-related cataract, it is essential to perform gonioscopy to identify increased pigment deposition, narrowing of the angle and compression of the angle structures to identify suitable candidates for potential combination glaucoma surgery.

Several randomized clinical studies have shown IOP lowering associated with cataract surgery alone in patients with open-angle glaucoma (Samuelson, Samuelson, Vold).

The addition of a Schlemm’s canal-based MIGS device can lower IOP even further without changing the safety profile of the procedure. There are three different FDA-approved MIGS stents currently available: the iStent, the iStent Inject, and the Hydrus Microstent.

Currently, the Hydrus is my “go-to” stent in patients with glaucoma and cataract. Removal of the cataract opens Schlemm’s canal and expands the trabecular meshwork.

The Hydrus Microstent is multi-modal by creating a large opening through the trabecular meshwork and dilating and scaffolding the conventional pathway through which fluid exits the eye.

It further enhances aqueous outflow through three mechanisms of action: trabecular meshwork bypass, expansion of Schlemm’s canal, and greater access to collector channels.

The bypass feature eliminates resistance to aqueous flow related to the effects of material build up in the trabecular meshwork, and the expansion of the canal over three clock hours of the circumference of the eye allows for optimal access to multiple collector channels.

Despite its complex design, the Hydrus Microstent is approximately the size of an eyelash -small enough that it is typically never felt or seen by the patient.

The procedure
Inserting the Hydrus is an elegant procedure. It has an intuitive delivery system that is easy to learn. It is easy to confirm by visual inspection that you are in the right place.

Canal stenting with Hydrus leads to a robust ouflow of aqueous to the veins for several clock hours, as may be confirmed using a small injection of trypan blue. Several clock hours of blue dye are readily observed in aqueous veins after Hydrus implantation. 

Alternatively, the aqueous veins may be blanched with BSS using the phaco tip. I also use it in my advanced glaucoma patients whom have not had glaucoma surgery and I have gotten very good results in these patients as well.

Clinical evidence
The clinical evidence for the Hydrus Microstent is convincing. Two prospective, multicenter, randomized controlled trials supporting the safety and effectiveness of the device have been published in Ophthalmology.3

In the HORIZON trial, the largest MIGS randomized study conducted to date, the Hydrus demonstrated significant reduction of IOP and medications in a wash out comparison for two years postoperative. 

As presented at the recent American Society of Cataract and Refractive Surgery meeting, 3-year follow-up has shown that IOP reductions are maintained, with 73% of eyes in the Hydrus group remaining medication free with a safety profile similar to phacoemulsification alone, and no significant change in endothelial counts.

Additionally, compared with phaco alone, Hydrus with phaco reduced the risk of incisional glaucoma surgery by 80% during the follow-up period.

There is a third study comparing the Hydrus to the iStent Trabecular Micro-bypass device in a prospective, multicenter randomized clinical trial.

Recently published in Ophthalmology, the COMPARE study demonstrated that the Hydrus is superior to two iStent devices in standalone surgery for reducing pressure and adjunctive medication use at 12 months4

Lasting results
The effect appears to be durable for at least 24 months. The Hydrus maintained significant reductions in medications and IOP. More importantly, significantly fewer glaucoma operations were required in the Hydrus arm compared with two iStents arm after 2 years of follow up. 

This study suggests that trabecular bypass with 3 clock hours of canal stenting-with its assured access to multiple collector channels within the treated quadrant-decreases pressure compared with trabecular bypass alone, where interaction with collector channels is unpredictable.

I have had excellent results in my patients with the Hydrus Microstent that are in line with the published studies. In my experience using the Hydrus Microstent, this is the most powerful MIGS device that can be placed in patients with mild to moderate glaucoma at the time of cataract surgery. 

There are no serious risks or complications associated with the procedure. 

At times the stent has not been able to penetrate a thickened heavily pigmented trabecular meshwork. Also at times the iStent inject penetrated through both the inner and outer wall of the Schlemm’s canal and is actually implanted into sclera, reducing its efficacy. This has been confirmed by others with AS-OCT imaging of iStent.5

The Xen subconjunctival stent has been not been fullproof in that the 45 μm small lumen will often get obstructed with subconjunctivally or intraluminally. Intraluminal obstruction cannot be overcome with needling or external revision of the Xen.

As we know, many glaucoma patients, despite intervention may progress to a more advanced disease stage.

Seeing results

Cataract surgery and implanting the Hydrus Microstent at an earlier stage will often serve to preserve the health of the patient’s collector channel and provide benefit from the beginning to the end of the disease. This could result in longer-term eye health.

Having performed over 70 of these procedures in patients with glaucoma, not only can I lower the IOP and dramatically reduce the amount of medications needed, but also improve vision from cataract extraction and refractive lens exchange.

This is currently my initial approach to patients with open-angle and angle-closure glaucoma over the age of 50. This does not apply to persons with other types of secondary glaucoma such a neovascular or uveitic.

Conclusion
In the future, use of Hydrus may not be limited to combination with cataract surgery. 

In April 2017, the FDA granted Ivantis clearance to initiate a second IDE trial of the Hydrus Microstent. It was approved in 2018, based on results of the HORIZON trial. 

The SUMMIT trial will investigate the Hydrus in more challenging cases and will include 60 patients with advanced glaucoma for whom conventional therapies have proven unsuccessful. 

Patients in this trial will undergo standalone glaucoma surgery without combined cataract surgery.

References:

1. Harry A. Quigley, MDJohn D. Gottsch, MDJonathan Javitt, MDKuldev Singh, MD. Relationship between intraocular pressure and primary open angle glaucoma among white and black Americans: The Eye Survey. Arch Ophthalmol. 1991;109:1090-1095. 

2. Pfeiffer N, Feijoo JG, Fea AF, et al. A randomized trial of a Schlemm’s canal microstent with phacoemulsification for reducing intraocular pressure in open-angle glaucoma. Ophthalmology. 2015;122:1283-1293.

3. Samuelson TW, Chang DF, Marquis R, Flowers B, Lim KS, Ahmed IIK, Jampel HD, Aung T, Crandall AS, Singh K; HORIZON Investigators. A Schlemm canal microstent for intraocular pressure reduction in primary open-angle glaucoma and cataract: The HORIZON Study. Ophthalmology. 2019;126:29-37. 

4. Ahmed IK, Fea A, Au L, Ang RE, Harasymowycz P, Jampel H, Samuelson TW, Chang DF, Rhee DJ; COMPARE Investigators. A prospective randomized trial comparing Hydrus and iStent micro-invasive glaucoma surgery implants for standalone treatment of open-angle glaucoma: The COMPARE Study.Ophthalmology. 2019 Apr 26. pii: S0161-6420(18)31710-X. doi: 10.1016/j.ophtha.2019.04.034. [Epub ahead of print]

5. Gillmann KBravetti GEMermoud AMansouri K.A prospective analysis of iStent inject microstent positioning: Schlemm’s canal dilatation and intraocular pressure correlations. J Glaucoma. 2019 May 1. doi: 10.1097/IJG.0000000000001273. [Epub ahead of print]

Related Videos
© 2024 MJH Life Sciences

All rights reserved.